Technologies Developed
|
|
|
|
|
|
|
|
You are here : Home > Technologies Developed >
Testing and Measuring Instruments |
Testing and Measuring Instruments |
|
|
Application
Impulse testing of electrical and electronic equipment such as transformer,
energy meter, switchgear etc. |
|
Specification |
- Input supply : 230VAC, 50 Hz.
- Output voltage peak : 0 to 6 kV
- Open circuit waveform characteristic (equivalent load of 10 k Ohm):
- Front time : 1.2 micro seconds ± 30%
- Tail time : 50 microseconds
± 20%
- Short circuit characteristics (impedance 0.1 Ohm):
- Front time : 8 microseconds ± 20%
- Effective output impedance : 2 Ohm
|
Salient Features |
- Compact design
- Fully safe operation due to protected panel
- Positive and negative polarity pulse selection
- Variable output range from 0 to 6 kV.
- Solenoid operated sphere gap trigger arrangement.
- Charging voltage display by digital kV meter.
- Oscilloscope output is provided to see the wave shape.
- Charging capacitor discharge facility provided inside after operation.
- Charging supply isolation just before operation of sphere gap.
Cost per Unit: Approximately Rs. 1,35,000/-
|
|
Application
Useful in type testing of RCCB as per IS:12460(Part-1)-2000 specification |
|
Specification |
- As per requirements of IS: 12640 (Part 1) - 2000
- 0.5 µ sec / 100 kHz ring wave
- Peak value: 200 A ± 10%
- Virtual front time: 0.5 µ sec ± 30%
- Period of the following oscillatory wave = 10 µ s ± 20%
- Each successive peak: about 60% of the preceding peak
|
Salient Features |
- Indigenously developed
- Not manufactured in India
- Meets the requirements of IS: 12460 (Part-1) – 2000
Cost: Approx. Rs. 75000/- per unit
|
|
Application
Test equipment is required testing of energy meter |
|
Specification |
- Maximum current : 3000A AC rms, half cycle
- Current control : Through Variac and Voltage
display
- Standard applicable: IS :13779, CBIP report 88 for direct connected
meters
|
Salient Features |
- Reliable electronic control to avoid successive multiple triggering
- Guaranteed half cycle
- Push button control for trigger and reset special features
Cost per Unit: Approx. Rs. 1,35,000/- lakh
|
|
Application
In the testing of energy meter as per IS:13779-1999 |
|
Specification |
- Eight 7-segment displays for displaying different tests
- Feathers touch keypad to program the system in different 3 tests
- Minimum sampling interval of 20 milliseconds for SYNC operation
- Multi-level LED indication for different test
- A RS-232 port for remote operation
- PC based software through which whole system can be operated from remote PC
- The format of test display is T.E.S.T-1
- Operating voltage for the system is 230 VAC
- Input signal voltage (output of instrument) 230/ 110 VAC single/ three phase
|
Salient Features |
- All three tests can be performed on a single set up
- Serial communication provided
- PC software stores the test details with date and time
Cost per Unit: Approximately Rs 50,000/-
|
|
Application
To conduct glow wire test on insulating materials
used in LT Switchgear, Energy meters, Appliances, Wiring accessories etc.
|
|
Specification |
- Apparatus conforms to IS: 11000 (Pt. 2/Sec.1)-1984/ IEC 60695-2-10:2000
- Glow wire loop: Nickel – Chromium (80 / 20)
- Thermo Couple: Type K, Sheathed 0.5 mm outer diameter
- Temperature Range: 550 ºC ± 10 ºC, 650 ºC ± 10 ºC, 750 ºC ± 10 ºC, 850 ºC ± 10 ºC,
960 ºC ± 10 ºC
- Accuracy: ± 0.5 %
|
Salient Features |
- Indigenously developed
- Meets all requirements specified in IS: 11000 – 1984
Part 2 / Sec 1)/ IEC 60695-2-10:2000
Cost: Approx. Rs. 90,000/- per unit
|
|
Application
In lamps and luminaire industries to determine mean
effective life of lamps |
|
Specification |
- Input signal :- 10 V to 270 V AC
- Range :- 0 to 99999.9999
- Supply voltage :- 180 V to 270 V
- Humidity :- 95 % rh°
- Operating Temperature :- 0 – 70 °C
- Accuracy class :- 0.1 %
|
Salient Features |
- Micro controller based system
- Liquid Crystal Display : (4 – digit after decimal point)
- Memory capacity for more than one month
- Reset facility
Cost: Approx. Rs. 10000/- per unit
|
|
Application
To conduct short circuit test on MCBs, Transformer
& LT Switchgear products at controlled switching |
|
Specification |
- Setting of angle from 0 to 360 degree in one degree resolution
- Accuracy 0.5º
- Synchronization signal voltage: 230/110 Volt ac, works upto 10% of input voltage
- Sampling interval : 20 milli seconds
- Operating voltage for the system: 230 Volt ± 10 % ac
|
Salient Features |
- Eight 7-segment displays for displaying DEGREE and operating MODE
- Feather touch keypad to program the Unit in different modes and setting the points
on wave switching angle in degree
- LED Indication for Trigger Pulse, Sync Pulse, Firing Angle
- The format of MODE as LOC (LOCAL) or RE (REMOTE)
Cost: Approx. Rs. 50000/- per unit
|
|
Application
Field study of Harmonics, Waveform Analyzer, Oscilloscope |
|
Specification |
- Input voltage range : 0 – 1000 V
- Step down ratio : 40 & 200
- Input impedance : 1 MW
- Operating voltage for the system: 230 volt +/- 10 % AC
|
Salient Features |
- Ground is isolated
- Output of the differential module is floating and can be directly connected to C.R.O.
Cost: Approx. Rs. 15000/- per unit
|
|
Application
For testing of Energy meters, electrical transducers
as per IEC : 61000 – 4-12 |
|
Specification |
- Input Voltage: 230 V ac, 50 Hz
- Output voltage peak: 4-15 kV peak
- Open current wave form characteristic (equivalent, greater or equal to 10 K ohm)
Front Time : 1.2 µs ± 30%,
Tail Time : 50 µs ± 20%
- Short circuit waveform characteristics (Load smaller or equal
to 0.1 ohm) Front Time : 8 µs ± 20%,
Tail
Time : 20 µs ± 20%
- Effective out put impedance: 2 Ohms
- Phase shifting: 0 to 360º
- Impulse can be superimpose on supply voltage for the load current
of 15 Amp.
|
Salient Features |
- Compact design
- Fully safe operation
- Positive and negative polarity pulse selection
- Variable output voltage from 4 – 15 kV
- Solenoid operated sphere gap trigger arrangement
- Output voltage peak display by digital kV meter
- Charging supply isolation just before the operation of sphere gap (trigger)
Cost: Approx. Rs. 6.0 lakhs per unit.
|
|
Application
To conduct induced failure test on GLS lamps as per
IS: 15518 (part 1) 2004 |
|
Specification |
|
Input voltage |
230 V ac, 50 Hz |
|
Output Voltage peak |
2.8kVp – 3.1kVp(for lamp rated upto 100W) |
|
|
2.4 kVp – 3.1 kVp(for lamp rated above 100W) |
|
Rise time |
< 1 µ sec |
|
Tail Time |
<10 µ sec for lamps rated above 100W |
|
|
8-20 µ sec for lamps rated upto 100W |
|
Angle |
70º ± 10º |
|
|
|
|
|
Salient Features |
- Lamp rating between 200 V – 250 V
- No control set up required
- Single switch for triggering
Cost: Approx. Rs. 1.5 lakhs per unit
|
|
|
|