Calibration
|
|
|
ERDA is Accredited / Recognized by the following organizations. The list is only
typical, not exhaustive.
|
|
National Accreditation Board for Testing & Calibration Laboratories (NABL) Govt.
of India
|
|
Intertek (ASTA-BEAB) for Switchgear, Cables & Transformers
|
|
Underwriters’ Laboratories (UL) for Certification Testing of Contactors, Pilot Lamps
and Pilot Switches
|
|
TÜV Rheinland (India) Pvt.Ltd.,
|
|
Certification after Recognition of Agent's Testing (CARAT), TÜV-PS Germany
|
|
Dept. of Atomic Energy (DAE), Govt. of India for LOCA Qualification and Seismic
testing of electrical equipment
|
|
Bureau of Indian Standards (BIS)
|
|
Canadian Standards Association for LT Switchgear & Capacitors
|
|
Dept. of Revenue, Ministry of Finance, Govt. of India
|
|
Dept. of Scientific & Industrial Research (DSIR), Govt. of India
|
|
Commissioner of Electricity, Govt. of Gujarat for Household Electrical Appliances
|
|
Gujarat Electricity Regulatory Commission, Madhya Pradesh Electricity Regulatory
Commission and Rajasthan State Electricity Regulatory Commission for Energy Meters
|
|
|
Calibration plays a major and vital role in any quality management system.
One of the important requirements in a quality system for any organization is a
valid calibration system for all measurements undertaken. ERDA’s standards
have traceability to NPL, New Delhi/ international standards. ERDA is recognized
by the National Accreditation Board for Testing and Calibration Laboratories, Govt.
of India.
|
|
|
|
Following instruments / parameters can be calibrated:
|
|
Parameter Instruments
|
Range
|
DC Current
|
0-1000A
|
AC Current
|
0-1000A
|
DC Voltage
|
0-1050V
|
AC Voltage
|
0-1050V
|
Resistance
|
0-330 M Ω
|
Power (UPF/LPF) (Active, Reactive, apparent)
|
0-20A, 75 V /
1000A*, 1000V
|
Power Factor
|
0.1 lag/lead to Unity
|
Frequency
|
0.05-10MHz
|
Insulation Resistance
|
Up to 1TΩ, 5 kV
|
Capacitance meters
|
0.33 nF to 40mF,
|
Resistance
|
100 µ Ω - 1 T Ω
|
Time
|
1 mSec to 90000 Sec
|
Universal Calibration System / Calibrators
|
As per manual
|
Oscilloscopes
|
As per manual upto 250M.Hz.
|
Transducers, Relay testing kits, Primary/Secondary injection kits, CB analysers/ELCB
testers, etc.
|
Same as for V,I, Power,pf, frequency, temperature, time, etc..
|
Energy Meters / Calibrators
|
55 V – 290 V Direct current up to 120 A; 3 Ph-3-Wire / 3 Ph-4- Wire / 1 Ph-2-Wire
|
High Voltage
|
400 kV DC & 1000 kV AC
|
Impulse measuring system*
|
Up to 3000 kvp
(At ERDA as well as at site)
|
Partial Discharge Detector*
|
Multiple Ranges
|
Partial Discharge Calibrator*
|
Multiple Ranges
|
Standard Capacitor*
|
Multiple Ranges
|
C – DF Calibrator*
|
Multiple Ranges
|
Capacitance & Tan-delta Bridge*
|
Multiple Ranges
|
Capacitive Voltage Divider*
(C1- C2 method)
|
Multiple Ranges
|
At ERDA, Vadodara
- Calibration of CT and VT Analyzers.
- Calibration of Standard Voltage Transformers up to 220kV Voltages and up to 0.05 accuracy class.
- Calibration of Current Transformers up to 8000A, up to 0.05 Accuracy class.
- Calibration of Turns Ratio Meter for 2 to 2000 Turns Ratio.
- Calibration of CTPT Bridge (AITTS).
|
At Site and Mobile Facility. - Calibration of CT and VT Analyzers.
- Calibration of Standard Voltage Transformers up to 33kV Voltage and up to 0.05 Accuracy class.
- Calibration of Current Transformers up to 6300A, up to 0.05 Accuracy class.
- Calibration of Turns Ratio Meter for 2 to 300 Turns Ratio.
- Calibration of CTPT Bridge (AITTS).
|
|
|
Items which can be calibrated
|
Range
|
Digital Vernier Caliper / Vernier Caliper
(L. C. 0.01 mm & 0.02 mm)
|
0 - 300 mm
|
Digital Micrometer / Micrometer
(L. C. 0.001 mm & 0.01 mm)
|
0-25 mm
|
Plunger Dial Gauge
(L. C. 0.001 mm & 0.01 mm)
|
0-12.5 mm
|
Verification of uniaxial testing machines, Dynamometer etc. at site (Accuracy
– 1% )
|
Tension Mode - 100N to 200 kN;
Compression Mode - 100N to 500kN
|
Load Cell calibration (At ERDA)*
(Accuracy – 1% )
|
Tension Mode - 100N to 200 kN;
Compression Mode - 100N to 500kN
|
Pressure Gauges*
|
>10-700 kg/cm2 for accuracy ± 0.5% of FSD
|
*These items are not covered under our scope of NABL accreditation for the present
|
|
|
Temperature Simulation (Indicator/controller/scanner, etc.
|
-250oC to 2500oC
|
Temperature Measurement (Sensors, bath, etc.)
|
-30oC to 1000oC
|
|
|
Calibration of CT and VT Analyzers.
|
Calibration of Standard Voltage Transformers up to 220kV Voltages and up to 0.05 accuracy class.
|
Calibration of Current Transformers up to 8000A, up to 0.05 Accuracy class.
|
Calibration of Turns Ratio Meter for 2 to 2000 Turns Ratio.
|
Calibration of CTPT Bridge (AITTS).
|
|
|
Calibration of CT and VT Analyzers.
|
Calibration of Standard Voltage Transformers up to 33kV Voltage and up to 0.05 Accuracy class.
|
Calibration of Current Transformers up to 6300A, up to 0.05 Accuracy class.
|
Calibration of Turns Ratio Meter for 2 to 300 Turns Ratio.
|
Calibration of CTPT Bridge (AITTS).
|
|
|
Parameters
|
Products
|
Range
|
Luminous Flux
|
GLS Incandescent lamps
|
190 lm – 3300 lm (25 W – 200 W)
|
Compact Fluorescent Lamps
|
200 lm – 2000 lm (5W to 26 W)
|
High Pressure Sodium Vapour Lamp
|
4800 lm – 50000 lm (70 W to 400 W)
|
Metal Halide Lamp
|
10000 lm – 50000 lm (150 W to 400 W)
|
High Pressure Mercury Vapour Lamp
|
2000 lm – 26000 lm (80 W to 400 W)
|
Tubular Fluorescent Lamps
|
900 lm – 3500 lm (14 W to 40 W)
|
Colour coordinates
|
-
|
2700 K to 6500 K
|
|
|
The testing of Energy Meters is done for both users and manufacturers. The
tests for mechanical, electrical and thermal properties are performed as per IS:13010-1990,
IS:13779-1993 and IS:14697-1999. Endurance, impulse, climatic, vibration and
ingress protection testing ensure the reliability of the energy meter.
Sr.No.
|
Product
|
Standards
|
1
|
AC Induction Watt-hour Meters, Class 0.5, 1&2
|
IS:13010
IEC:60521
|
2
|
AC Static Watt-hour Meters Class 1&2
|
IS:13779
IEC:61036
|
3
|
AC Static Watt-hour meters Class 0.5 & 0.2
|
IEC:60687
|
4
|
AC Static Electrical Energy Meters (Trivectormeters)
|
CBIP Publication No. 304
|
5
|
Winding wires – enameled copper wires
|
IS:4800, 13730, 13778
|
6
|
Electromagnetic core (CRNGO)
|
IS:648,649, 1018
IEC:60404-2
ASTM:A343,A717, A718
|
7
|
Frame die Cast Aluminium
|
IS:617
|
8
|
Pinions – leaded brass/synthetic materials
|
IS:319,4253,2221,882
|
9
|
Counter frame – brass sheet
|
IS:410
|
10
|
Counter frame – Al sheet
|
IS:2657
|
11
|
Terminals – plated brass
|
IS:410,168
|
12
|
Gaskets synthetic rubber
|
IS:4253
|
13
|
Plastics
|
IS:4253,2221,882
|
|
|
Following products can be calibrated as well as Type tested at ERDA. Some
of the important products are:
Sr.No.
|
Product
|
Standards
|
1
|
Current Transformer
|
IS:2705
IEC:60044-1
|
2
|
Potential Transformer
|
IS:3156
IEC:60044-II
|
3
|
Testing of analog measuring instruments (ammeters, voltmeters, wattmeters, varmeters,
frequency meters etc.
|
IS:1248
|
4
|
Testing of digital measuring instruments
|
IS:13785
|
5
|
Testing of insulation tester
|
IS: 2292
|
6
|
Transducer
|
IEC: 60688
|
7
|
Energy Meter
|
IS: 13010/ IS:13779/ IS:14697
|
|
|
|
|
|
|
|
|
|
|