Technologies Developed
|
|
|
|
|
|
|
|
You are here :
Home > Technologies Developed > Others |
Others |
|
|
Application
For self training on power system network |
|
Specification |
- Two modules ( i ) Load flow ( ii ) Transient Stability
- Facility to change the data of different elements through dialog boxes
- Results of load flow can be seen both graphically as well as in text
file
|
Salient Features |
- User friendly and flexible GUL, compatible with any Windows package with minimum
required facilities
- Violation of constraints after execution of load flow is indicated by blinking the
corresponding element with sound
- Transient stability can be executed with different fault options. Voltage
regulator and Governor effects on the stability can be simulated
- After execution of transient stability results can be seen through different
plots
Cost: Rs. 1.5 Lakhs
|
|
Application
Software for Generation Scheduling |
|
Specification |
- Two modules (i) Short Term Load Forecasting & (ii) Generation Scheduling
- Aid to generate dispatch instructions to generating stations
- Cumulative display of Plant Load Factor (PLF) and weekly PLF
|
Salient Features |
- Short Term Load Forecasting (STLF) based on day of the week effect
and load inertia
- Dispatch instructions based on forecasted weekly load
- Constraints are incorporated for generation capacity of the plant, minimum level
based on normative PLF level
- Minimum costing based on variable cost of IPPs and SEB’s generation sources
|
Application
Water pumping for Irrigation, gardening and domestic
pumping |
|
Specification |
- Delivery: ¾”
- Head: 3 M
- Suction Head: 1M
- Discharge: 5 lpm
- Human Operated
|
Salient Features |
- No Fuel required for operating the pump. Works on Human by power pedalling
- Capable of irrigating 1-2 acre land without any cost of electricity, diesel etc.
- Being a mobile unit can be used for irrigation, gardening and domestic pumping applications
Cost: Approx. Rs. 1,000/- per unit
|
Application
For reactive power compensation in the distribution
system |
|
Specification |
- Study on different type of compensator
- Simulation of Compensator:- Shunt type reactive power compensator
- Supply system:- Three phase four wire LT distribution system
- Supply Voltage:-240 Vrms per phase.
- Load to the system :- 500 kVA
|
Salient Features |
- Simulations carried for various conditions for both balance loads and unbalance
loads.
- The results provide important base line for developing Static VAR Compensator
|
Application
Online reconditioning of oil of transformer upto 66kV |
|
Specification |
- Capacity – One kL/ day
- Weight – 500 kg
- Power Consumption – 5.25 kW
|
Salient Features |
- Online transformer oil reconditioning unit useful in remote areas
- Easy to operate and maintained by a skilled labour
- Portable and light weight
- Useful for removal of moisture and polar compounds from oil
Cost: Depends on capacity of filtration
unit
|
|
|
|